24 Hour Roof Replacement Guarantee File a Roofing Insurance Claim Today
Residential License #890459 Commercial License #3667
Emergency 2.jpg?ver=2.3

Hurricane Straps and How They Anchor a Rafter to the Wall

A galvanized metal strap nailed across the joint where a wooden roof rafter meets the top plate of a framed wall.

A hurricane strap is a stamped metal connector, usually smaller than your hand, that ties a rafter or truss to the wall below it. It costs a few dollars and it’s one of the highest value pieces of hardware on a house in south Louisiana.

Wind doesn’t push a roof off. It lifts, and the connection at the top of the wall is where that lift gets resisted. TurnKey Roofers looks at these connections whenever a roof is open in the New Orleans area.

If you want yours checked during your next roof job, use the contact page or call (504) 732-0336.

asbetos roofing removal new orleans

Key takeaways

  • Hurricane ties connect each rafter or truss to the wall top plate so uplift has somewhere to go.
  • The Building America Solution Center describes the goal as a continuous load path, where every connection is a link in a chain that’s only as strong as its weakest link.
  • Residential code requires roof assemblies to resist uplift, with connections designed to Table R802.11 and a simplified path allowed where uplift per rafter is 200 pounds or less.
  • Connector capacities are published for a specific fastener schedule, so the nails named in the instructions are part of the product.
  • LSU AgCenter says toenailing trusses or rafters often isn’t sufficient in high winds, and recommends straps that wrap over the rafter.
  • Sheathing loss is one of the most common structural failures in hurricanes, so deck fastening matters alongside the ties.

What a hurricane strap actually does

When wind flows over a roof it creates suction on the upper surface, particularly at edges and corners. LSU AgCenter puts it well in describing a very low-pitched roof: it acts like an airplane wing in high winds.

The Building America Solution Center traces where that force goes. High winds lift the roof upward, the force transfers from the roofing material to the roof sheathing, and from the sheathing into the trusses or rafters.

The rafter then has to hold onto the wall. A hurricane tie is the piece of metal that makes that joint capable of resisting the pull, instead of relying on a couple of nails driven at an angle.

The continuous load path

A single strong connection doesn’t save a house. The Building America Solution Center uses a chain analogy: each connection and structural member is a link, the chain must be continuous, and it’s only as strong as the weakest link.

That chain runs from the roof covering, through the sheathing, into the rafters, down through the ties into the top plate, through the wall studs, and finally into the foundation. LSU AgCenter’s LaHouse demonstration home applies the same principle, with hurricane hardware and structural sheathing tying the roof to the walls and the walls to the foundation.

It’s also why a strap on its own isn’t a hurricane retrofit. Strengthening one link moves the failure to the next weakest one.

What the code asks for

Residential code requires roof assemblies to have uplift resistance, and rafters have to be attached to the supporting wall with connections capable of resisting the uplift force. That force comes from Table R802.11 or from accepted engineering practice.

There’s an exception for lighter loads. Where the uplift force per rafter or truss doesn’t exceed 200 pounds as determined by Table R802.11, the standard framing connections in Table R602.3(1) are permitted.

Trusses get their numbers from the truss design drawings for the ultimate design wind speed shown on the construction documents. The Building America Solution Center notes that Table R802.11 sets out the pounds of uplift a connector must withstand for a given design wind speed, roof pitch and rafter or truss spacing.

Variable Effect on the required connector Where it comes from
Design wind speed Higher speed means higher uplift per connection Table R802.11
Roof span Wider span collects more uplift per rafter Table R802.11
Rafter or truss spacing Wider spacing concentrates load into fewer connections Table R802.11
Exposure category Open exposure increases the load Table R802.11
Roof pitch Changes the uplift each connection carries Table R802.11

Nails, screws and why the fastener schedule matters

Connector manufacturers publish load values that are only valid with the fasteners named in the instructions. Simpson Strong-Tie’s engineering blog notes that many hurricane ties have been evaluated with 8d by 1.5 inch nails, while some require a longer 8d common nail at 2.5 inches and others need a larger diameter 10d nail.

Substituting a screw because it’s what was in the truck doesn’t give you the published capacity. The nail diameter, length and the number of holes filled are all part of the tested assembly.

Filling every hole matters too. Simpson Strong-Tie points out a common error where an H2.5A is installed on a nominal 2×4 bottom chord and the upper nail holes miss the wood entirely, which drops the capacity sharply.

One more design point worth knowing. The same blog notes that when a connector resists lateral loads, its capacity to resist uplift is reduced, so a connector doing two jobs can’t be assumed to deliver both at full value.

How many go on each rafter

  • The usual arrangement is one connector at every rafter or truss to top plate joint, not every second one.
  • LSU AgCenter’s retrofit guidance says to install them where each roof rafter meets the exterior wall, and to use straps that wrap over the rafter for best protection.
  • Single-sided ties such as the H2.5A fasten from one face, while U-shaped designs such as the H1 allow fastening from both sides where the framing width fits.
  • Where roof and wall framing members don’t line up, Simpson Strong-Tie notes two connectors can be used to complete the load path.
  • The required capacity, and therefore the connector model, comes from the uplift number for your wind speed, span, spacing, exposure and pitch.

Anyone quoting you a strap count without reference to those variables is guessing. On a retrofit, a structural engineer or a contractor working to the table should set it.

Retrofitting an older New Orleans house

Plenty of houses here predate any requirement for metal roof-to-wall connectors. LSU AgCenter lays out a retrofit approach that fits naturally into a re-roof, since the best access is from above.

  1. Remove the bottom row of roof sheathing at the eave lines while the covering is off.
  2. Check whether the roof is already fastened to the top of the exterior wall with metal straps or clips. They’re usually hard to see from the attic because of insulation.
  3. If there are none, install them where each roof rafter meets the exterior wall, using straps that wrap over the rafter where possible.
  4. Re-fasten the roof sheathing, adding nails four inches apart at the corners, ridges and eaves where wind forces concentrate.
  5. Use ring shank nails for the deck. The FORTIFIED standard described by LSU AgCenter calls for 8d ring shank nails, which double the wind uplift resistance of the roof deck.
  6. Seal the deck seams before the underlayment goes down, which LSU AgCenter says cuts water entering the home by 95 percent if the covering is damaged.

LSU AgCenter is candid that several of these recommendations aren’t standard building practice in Louisiana, and suggests homeowners raise them with their roofing contractor directly. Our page on roof weatherproofing covers how we handle the rest of the assembly.

What straps can’t do on their own

Ties protect one link. The Building America Solution Center notes that sheathing loss is one of the most common structural failures in hurricanes, which happens above the tie rather than at it.

Gable ends are the other weak point. The same guidance explains that wall bracing keeps a rectangular wall from shearing into a parallelogram under high wind and seismic loads, and some jurisdictions limit the accepted methods to 3/8 inch or thicker plywood or OSB.

Attic vents matter as well. The FORTIFIED approach requires all attic ventilation to prevent wind-driven rain from entering the attic, either through vents designed to survive strong winds or with covers fitted during severe weather.

The top of the chain gets overlooked most often. LSU AgCenter describes drip edge at the eaves as an important part of keeping the shingles on the roof, because the starter strip adheres to it, and drip edge on the rakes as the anchor that holds the underlayment against wind.

Deck thickness is worth a mention too. LSU AgCenter suggests half inch plywood as good and 5/8 inch as better when replacing large sections, fastened to rafters with 2 to 2.5 inch screws or 8 to 10 penny galvanized nails, with ring shank the preferred choice.

None of it helps if the nails split the plywood. The same guidance warns against using too many fasteners, since overnailing weakens the panel it’s meant to hold down.

Frequently asked questions

Do hurricane straps really work?

Yes, when they’re part of a complete load path and installed with the specified fasteners. The Building America Solution Center describes steel connectors, strapping or screws at roof-to-wall connections as the way to increase uplift resistance along that path, and treats the path as a chain where the weakest link governs. LSU AgCenter is direct about the alternative, noting that the common practice of toenailing trusses or rafters often isn’t sufficient to hold a roof in place in high winds.

Should hurricane straps be nailed or screwed?

Use exactly what the connector’s own instructions call for, which is usually a specific nail. Simpson Strong-Tie’s engineering blog notes that many hurricane ties are evaluated with 8d by 1.5 inch nails, some require an 8d common nail at 2.5 inches, and others need a larger diameter 10d nail. Published load values assume that fastener in those holes, so a substitution puts you outside the tested assembly and outside the published capacity.

How many hurricane straps per rafter?

One connector at each rafter or truss to top plate joint is the normal arrangement, with the model chosen to meet the uplift force for your wind speed, roof span, rafter spacing, exposure category and pitch from Table R802.11. LSU AgCenter recommends installing them where each roof rafter meets the exterior wall and using straps that wrap over the rafter. Where roof and wall framing don’t line up, Simpson Strong-Tie notes two connectors may be needed to complete the connection.

Can hurricane straps be added without removing the roof

Sometimes, from inside the attic, though access is awkward and the work is slower. LSU AgCenter’s approach takes advantage of a re-roof by removing the bottom row of sheathing at the eaves, which exposes the joint cleanly and lets the sheathing be re-fastened properly afterward. If a roof replacement is already on the calendar, that’s the cheapest moment to do it.

Ask about the roof-to-wall connection before the deck goes back on

The window for this work is short, and it closes the moment new sheathing is nailed down. If your roof is due for replacement, tell us you want the connections checked and we’ll look while the eave is open.

Call (504) 732-0336 for a free estimate, and ask about our unlimited wind warranty while you’re at it.

Sources

Common questions about working with us

Yes we do, we offer 50 year non pro-rated warranty and 10 year workmanship warranty. We also offer 15 year unlimited wind warranty even from a named storm.

Turnkey roof repair is a comprehensive service where the entire roof repair process is managed from start to finish by a single provider. This includes assessment, planning, execution, and final inspection.

The TurnKey process includes a thorough roof inspection, detailed project planning, sourcing of materials, execution of repairs, and a final inspection to ensure quality and client satisfaction.

The duration varies based on the extent of damage and the size of the project. A professional assessment will provide a more accurate timeline.

Look out for signs such as leaks, missing or damaged shingles, sagging areas, or visible water damage in your ceiling. If you’re unsure, a professional assessment is recommended.

We work across New Orleans and 13 more communities: Metairie, Kenner, Harahan, River Ridge, St. Rose, Gretna, LaPlace, Covington, Mandeville, Madisonville, Slidell, Hammond and Baton Rouge. Call 504-732-0336 and we’ll confirm we cover your street.

Yes. Our 15-year unlimited wind warranty applies even when the damage comes from a named storm. It sits alongside our 50-year non-prorated warranty and 10-year workmanship warranty.

It depends on the size and pitch of the roof, the material you choose, and whether any decking or flashing needs replacing. After a free roof inspection, we give you a plan and a quote. For a breakdown by material and roof size, read our guide to roof replacement cost in New Orleans.

All posts Get My Free Estimate